THC10 Reptizoo Termostaati & Ajastin 600W

  • Sale
  • Regular price €84,90
Sisältää veroa


Advanced thermostat with LCD control unit and 2 outputs, A and B. For output A the user can program daylight start and end times; daytime temperature and night time temperatures; 4 on /off periods if required; the temperature difference between on / off switching. It can also be used to switch on a cooling device instead of a heater. Output B is timed, with up to 4 on / off periods each day. Ideal for daylight UV lights, or night time moon glo lamps. The control unit has a back up battery to remember the settings when disconnected from the mains.

Set up:

1 - Place the temperature probe inside the vivarium. Usually it can be placed in the centre to one side of the heat source to provide a temperature gradient. Drill a 7mm hole in wooden vivs. The control panel should be mounted for easy access, and the output block mounted safely out of the way. CONTROL UNIT OUTPUT BLOCK TEMPERATURE PROBE 2 - Plug the temperature probe into the control unit. Remove the battery saver tab from the control unit. Plug the output block into the mains power supply.

Programming the Control Unit:

The MODE button is used to cycle through the various settings, the display will flash which setting is to be set: T - Set the time T1 - Day start time T2 - Day end time ST1 - Day temperature; temperature difference between on / off; heat or cool. ST2 - Night temperature; temperature difference between on / off; heat or cool. A1 - Output A ON time A2 - Output A OFF time A3 - Output A ON time A4 - Output A OFF time A5 - Output A ON time A6 - Output A OFF time A7 - Output A ON time A8 - Output A OFF time (normally output A is left alone so it is on all day, reacting to temperature only) B1 - Output B ON time B2 - Output B OFF time B3 - Output B ON time B4 - Output B OFF time B5 - Output B ON time B6 - Output B OFF time B7 - Output B ON time B8 - Output B OFF time (normally output B is to switch day or night time lights on) The control unit comes pre-set so most of the settings are already done: -day time starts at 08:00 ; ends 18:00 (6.00pm) -day thermostat setting is 30° ; night setting 25° -output A only controlled by above temperatures To set: Press MODE and display will flash T Press and hold SET for 3 seconds and HOURS will flash. Use UP or DOWN to set correct hour. Press SET and minutes will flash. Use UP or DOWN to set correct minutes. If you have made a mistake press SET and it will go to hours, press set again and it will go to minutes. Press MODE when finished. Now the T1 will flash. (If you leave the unit alone after 5 seconds it will come out of setting mode.) Press SET for 3 seconds and the hour will flash. This is by default set to 8.00am. If you want to change it use the UP / DOWN buttons. Press SET and the minutes will flash, use UP / DOWN to change.

Press SET to go to hour setting again, or MODE to go to T2 setting. T2 will now flash. Press set for 3 seconds and hours will flash, use UP / DOWN to change. By default it is set to 18:00 (6.00pm). Press SET again and the minutes will flash, use UP / DOWN to change. Then press SET to come out of settings, or MODE to go to next item. If you chose MODE option from above ST1 will now flash. This is day time temperature setting and is preset to 30°. If you want to change it press SET for 3 seconds and then press UP / DOWN. Press SET and you will see temperature differential displayed. This is the difference between the on and off temperatures. It is preset to 1°, so if the temperature setting is 30°, output A will come on at 29° and go off at 31°. If you altered it to 4° then it would come on at 26° and go off at 34°. Press SET again and H (heat mode) will flash. Press UP / DOWN to change to C (cooling). WARNING: Only use C setting if you have a cooling device! Press SET to come out of setting mode, or MODE to go to next item. If you pressed MODE then ST2 will flash. This is the night temperature setting. Press SET for 3 seconds and the night temperature will flash. Use UP / DOWN to change. It is preset at 25°. Press SET to see the temperature differential, this is preset to 2°. Press SET to see H (heat mode), use UP / DOWN to change to C (cooling). WARNING: Only use C setting if you have a cooling device! Press SET to come out of setting mode, or MODE to go to next item. A1 will now flash. This is ON time for output A. It is recommended to leave this setting alone. If you want to change it press SET for 3 seconds and use UP / DOWN. Press SET again to change A2 setting, this is the off time for channel A. Press MODE to go to next setting. B1 will now flash. This is the output that is independent of temperature settings. Press SET for 3 seconds, and use UP / DOWN to set the hour on time. Press SET to alter the minutes using UP / DOWN. Press SET to enter B2 setting, this is the off time. Use UP / DOWN to change. Press SET to enter B3-B4, B5-B6, B7-B8 on off times. These can be left alone if you only want a single on / off function. Press MODE and unit returns to working status

Specifications:

Temperature can be set from -20° C to 50°C. Accuracy +/- 1°C. 24 hour clock. Daytime thermostat setting. Night time thermostat setting. Heating or cooling mode. Temperature differential can be changed between on / off settings. Output A max power - 600W. Output B max power - 600W. Control panel LED backlight. Display Symbols: T - Current itme. T1 - Day start time. T2 - Day end time. ST1 - Day time temperature setting for thermostat. ST2 - Night time temperature setting for thermostat. A1-8 - 4 on / off settings. B1-8 - 4 on / off settings, independent of thermostat settings. LL - Temperature too low. HH - Temperature too high. ET - Probe temperature.

Notes:

If you wish to revert back to factory settings there is a reset button on the rear of the control unit. The back up battery is CR2032. To change it pull out the battery drawer. The temperature display will show -- if the probe is not connected. If the temperature is too low or high it will show LL or HH